| Region | Specification | 
 | 
 | Euro | Euro | Euro | 
| Europe | R&TTE Directive Article 3.1(b) | EMC testing for a dualband GSM terminal device | EN 301 489-1 & EN 301 489 -7 | 4000 | 2000 | 6500 | 
| Europe | R&TTE Directive Article 3.2 (Spectrum Usage) | Radio testing, radiated spurious emissions measurement in GSM bands 900 and 1800 MHz | EN 301 511 | 3500 | 2400 | 4937 | 
| 
 | 
 | 
 | 
 | 7500 | 4400 | 11437 | 
| Testing for world region | Reference | Type of testing | Specifiaction | Notes | 
| Europe | R&TTE Directive Article 3.2 | Mobile Communication - Radiated Spurious Emission 2G | EN 301 511 | POS terminal, People tracker, Electricity meter | 
| Europe | R&TTE Directive Article 3.2 | Radio - Radio test EN 300 220 - Transceiver (Tx, Rx class 3) | EN 300 220 | Electricity meter (ISM 868 MHz) | 
| Europe | R&TTE Directive Article 3.1(b) | EMC - R&TTE acc. EN 301 489-7 (GSM) - AC/DC powered | EN 301 489-7 | POS terminal, People tracker, Electricity meter | 
| Europe | R&TTE Directive Article 3.1(b) | EMC - R&TTE acc. EN 301 489-3 (SRD) - add on testing | EN 301 489-3 | Electricity meter (ISM 868 MHz) | 
| Europe | R&TTE Directive Article 3.1(a) | Electrical safety test EN 60950-1, main powered device | EN 60950-1 | POS terminal, People tracker, Electricity meter | 
| Europe | R&TTE Directive Article 3.1(a) | Radio - SAR test - body position | EN 62311 | POS terminal, People tracker (GSM/GPRS 900/1800) | 
| Europe | 
 | European Union - R&TTE Notified Body Service - Annex IV Assessment - Licenced Device | 
 | POS terminal, People tracker, Electricity meter | 
| 
 | 
 | 
 | 
 | 
 | 
| USA/Europe | 
 | Mobile Communication - RF exposure calculation based on radio test results | CFR Part 47, EU recommendation 199/519/EEC | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| USA | 
 | Mobile Communication - Radiated Spurious Emission 2G | NAPRD | POS terminal, People tracker, Electricity meter | 
| USA | 
 | Mobile Communication - SIM/USIM Electrical conformance testing | NAPRD | POS terminal, People tracker, Electricity meter | 
| USA | 
 | EMC - FCC/Canada conducted and radiated up to 5GHz | CISPR 22, FCC part 15B | POS terminal, People tracker, Electricity meter | 
| USA | 
 | Radio - SAR test FCC - body position | FCC OET Bulletin 65 Supplement C | POS terminal, People tracker (GSM/GPRS 900/1800) | 
| USA | 
 | Radio - Radio test FCC part 15.249. Inclusive test report. | 47 CFR Part 15 | Electricity meter (ISM 915 MHz) | 
| USA | 
 | United States - Statemens of DoC (Declaration of Conformity) | 
 | Electricity meter (without ISM Band) | 
| USA | 
 | United States - TCB Approval Service - Licensed Device - Part 22/24/90/95 | 
 | POS terminal, People tracker (own FCC-ID) | 
| USA | 
 | United States - TCB Approval Service - Confidentiality fee | 
 | POS terminal, People tracker (own FCC-ID) | 
| USA | 
 | Mobile Communication - PTCRB certification handling | 
 | POS terminal, People tracker, Electricity meter | 
| 
 | 
 | 
 | 
 | 
 | 
| USA | 
 | Radio - Over the air test TRP / 1 band, 1 channel | CTIA OTA Performance | 3D | 
| USA | 
 | Radio - Over the air test TIS / 1 band, 1 channel | CTIA OTA Performance | 3D | 

 
            